1 rue Galilée, Espace Innova,
Parc Technologique de Soye
56270 Plœmeur, FRANCE
Measure the antioxidant efficacy of your ingredients, your products
with a FRAP test
The FRAP (Ferric Reducing Ability of Plasma) test is used to determine the reducing ability of compounds. It measures the capacity of an antioxidant to reduce ferric iron into ferrous cations. At WAINVAM-E, we offer to perform the FRAP test for you to quantify the power of your antioxidants.
Easy to use
Fast
Reproducible
Service description
The FRAP assay is a colorimetric electron transfer method for measuring the ability of an antioxidant to reduce the colorless ferric-tripyridyltriazine complex (Fe3+-TPTZ) to the blue ferrous tripyridyltriazine cation ([Fe(II)(TPTZ)2]2+), which absorbs in the UV spectrum at 593 nm. Point measurement in triplicate.
Elements
to provide
- Sample to analyze :
– For liquids : 1-5 ml
– For solids : 5-10 mg - Following information for each sample :
– Chemical nature: all chemical natures except radioactive elements.
– Form : solid (granular, powdery, etc …) liquid.
– Solubility : soluble or insoluble in the experimental conditions (culture medium).
– Concentration
– Shipping conditions: depending on the type of molecule and the packaging recommended to maintain its stability.
Results
The absorbance value obtained by spectrophotometry is proportional to the antioxidant capacity of the molecule to be tested.