The WAINVIEW relaxometer is equipped with a variable power green laser source that can be adapted to different applications. A pulsing system required for quantum detection allows the generation of very fast and precise sequences of light pulses to perform a T1 relaxometry protocol. The incident beam is then directed towards the sample containing NV-center diamonds through a microscope objective. The fluorescence signal from the diamonds is then backscattered and picked up by a very sensitive and fast detector to identify the low level of fluorescence in the pulse sequence. It can detect very small variations of magnetic field Thanks to optimised signal processing As NV fluorescent sensors are extremely photostable (and do not exhibit photobleaching) As only one drop of sample is needed on the usual microscope supports (slides, multi-well plates, Petri dishes, …) By choosing the specific diamond model for the desired application. Easy to use, thanks to the software developed specifically for this application Laser illumination 520nm Variable light power from 1µW to 1mW Warm-up time 1h for high accuracy and kinetic measurements Laser pulse and detection frequency up to 2MHz Detection filter > 650nm NEP (noise equivalent power) of the detector 1.3fW/Hz 1/2 Detector detection limit 2 pW RMS Measurement time 1 to 10 min, depending on the desired sensitivity Magnetic species detection limit 1nM to 1µM Size 70x70x70cm Power supply 230V / 50Hz Optimum temperature 22°C without interruption Storage -20°C to 55°C, humidity <65%. Lenses from x2 to x100, air or immersion Motorised platform High content screening platform Anti-vibration table Detection of magnetic species, such as : Evaluation of the effectiveness of antioxidant molecules that neutralise radical species in an extra-cellular medium for food or pharmaceutical applications. Detection of small temperature variations in oily or aqueous samples for quality control in industrial processes, particularly in the food and cosmetic industries. The WAINVIEW relaxometer works with the usual microscopy media (slides, multi-well plates, Petri dishes, …). Discover
the Relaxometer NV
Our WAINVIEW Software transforms the optical data into application-relevant numerical data for easy reading of results PRODUCT VISUAL
SOON
Avantages
The WAINVIEW Relaxometer stands out from other equipment for the detection of magnetic species because it allows for :
Sensitive
Fast
Reliable
Economical
Customised
Simple
The WAINVIEW Relaxometer can be used to study a variety of samples in both oily and aqueous environment. It is therefore suitable for many detection and evaluation applications, such as :
– Heavy metals in an aqueous sample, for eco-toxicological studies
– Free radicals in oils, lubricants and plastics as evidence of their oxidation
You prepare your samples with the nanodiamond kits and solutions chosen according to your applications.
The data are controlled and processed with our WAINVIEW Software This equipment is intended
for the following
application fields Do not hesitate to contact us if you need any further information
Quantum sensors
Oxidative stress
Functionalisation of nano-diamonds
Metrology